MR019R Air conditioning and ventilation system Teaching Equipment Educational Equipment Air Conditioner Trainer
Manual or automatic operation by PLC; use of real components
Features - complete air conditioning and ventilation system for laboratory operation
- high practical relevance due to real dimensions and use of commercial components
- manual or automatic operation by PLC Learning objectives/experiments
- practice-oriented principles of air conditioning and ventilation technology
- design and maintenance of an air conditioning and ventilation system
- principles of room air conditioning (h-x diagram)
- explanation of components: filter, air heater, air cooler, humidifier, condensing unit, PLC, flaps, outlets
- function of safety devices
- measurement of pressure curve and pressure losses
- effect of air cooler, air heater and humidifier on the state of the air at the outlet
- investigation of the control behaviour of an automatic air conditioning controller,
determination of limiting factors
Specification
[1] practice-oriented air conditioning and ventilation system with 2 independent system components: main unit and water chiller
[2] manual or automatic operation via PLC
[3] main unit with air duct, ventilator, air conditioning system
[4] air conditioning system with air cooler, electric air heater, humidification
[5] hoses connect air cooler to water chiller
[6] air duct from hot galvanised sheet with sight window and pressure measurement connections to record pressure curves
[7] air duct with filter, multi-leaf damper, ceiling vent, protective grating, ventilation grille, fire protection flap, inspection flap, sound insulation link, smoke detector
[8] refrigerant R410A, GWP: 2088
Contact: Elean Lin
Phone/Wechat: +86 15153106200
Whatsapp: +86 15153106200
Email: [email protected]
Add: Building No. 3 Double Innovation and Creation Industry Center, No.803 KeYuan Road, High Tech Zone, Jinan, Shandong, China